ALDOSSEL=VBAT, MLDOBSEL=LOW, ALDOBSEL=LOW, MLDOSSEL=VBAT, DLDOBSEL=LOW, DLDOSSEL=VBAT
Control
| ALDOBSEL | Analog LDO Bias Select. 0 (LOW): Select a low bias for the analog LDO. 1 (HIGH): Select a high bias for the analog LDO. | 
| ALDOSSEL | Analog LDO Source Select. 0 (VBAT): Select the VBAT pin as the input voltage to the analog LDO. 1 (DCDC): Select the output of the DC-DC converter as the input voltage to the analog LDO. | 
| MLDOBSEL | Memory LDO Bias Select. 0 (LOW): Select a low bias for the memory LDO. 1 (HIGH): Select a high bias for the memory LDO. | 
| MLDOSSEL | Memory LDO Source Select. 0 (VBAT): Select the VBAT pin as the input voltage to the memory LDO. 1 (DCDC): Select the output of the DC-DC converter as the input voltage to the memory LDO. | 
| DLDOOVAL | Digital LDO Output Value Select. | 
| DLDOBSEL | Digital LDO Bias Select. 0 (LOW): Select a low bias for the digital LDO. 1 (HIGH): Select a high bias for the digital LDO. | 
| DLDOSSEL | Digital LDO Source Select. 0 (VBAT): Select the VBAT pin as the input voltage to the digital LDO. 1 (DCDC): Select the output of the DC-DC converter as the input voltage to the digital LDO. |